NSN 5905-00-922-4852 Resistor Variable Nonwire Wound, Resistor Variable N manufactured by Paeaeesikunta, Raytheon Technical Services Company, Thales Atm Inc, Butler National Corp, Bourns Inc is available within ASAP Part Service’s ready-to-ship inventory. Owned and operated by ASAP Semiconductor, ASAP Part Services has over 6 billion parts within its inventory including 412-1799, 432414, 869020-0503. ASAP is committed to streamlining the parts procurement process for our customers. We make it easy for our customers to search through billions of parts to find the exact part they are looking for.
A dedicated ASAP account manager is ready to help solve any procurement issues or needs that a customer may have. As a company we are quick and responsive meaning we can deliver a part within an AOG timeframe. Quality control is at the center of all that we do. Each and every NSN 5905-00-922-4852 part is subject to numerous quality checks that are designed to screen out any part imperfections or validity issues. Subject a request for quote for NSN 5905-00-922-4852 part today and allow us to simplify your procurement process.
Alternative NSN: 5905-00-922-4852 |
Item Name:Resistor Variable Nonwire Wound |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5905 Resistors |
NCB Code: USA (00) |
Manufacturers: Paeaeesikunta , Raytheon Technical Services Company , Thales Atm Inc , Butler National Corp , Bourns Inc |
Part No Part No
|
Manufacturer NSN Parts
|
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
412-1799 | Paeaeesikunta | resistor variable nonwire wound | Avl | RFQ |
432414 | Raytheon Technical Services Company | resistor variable n | Avl | RFQ |
432414 | Thales Atm Inc | resistor variable nonwire wound | Avl | RFQ |
869020-0503 | Raytheon Technical Services Company | resistor variable n | Avl | RFQ |
869020-0503 | Thales Atm Inc | resistor variable nonwire wound | Avl | RFQ |
B208013-0000 | Thales Atm Inc | resistor variable nonwire wound | Avl | RFQ |
B208013-0000 | Raytheon Technical Services Company | resistor variable n | Avl | RFQ |
B208013-0000 | Butler National Corp | resistor variable nonwire wound | Avl | RFQ |
RJ12-50K0HMP0RM10PCT | Bourns Inc | resistor variable nonwire wound | Avl | RFQ |
RJ12-50K0HMP0RM10PCT | Raytheon Technical Services Company | resistor variable n | Avl | RFQ |
RJ12-50K0HMP0RM10PCT | Thales Atm Inc | resistor variable nonwire wound | Avl | RFQ |
RJ12CL503 | Thales Atm Inc | resistor variable nonwire wound | Avl | RFQ |
RJ12CL503 | Raytheon Technical Services Company | resistor variable n | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR W/MOUNTING HOLES/SLOTS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1.300 INCHES MINIMUM AND 1.340 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 0.769 INCHES MINIMUM AND 0.861 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.093 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0.100 INCHES MINIMUM AND 0.130 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0.060 INCHES MINIMUM AND 0.080 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.240 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0.180 INCHES MINIMUM AND 0.200 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0.300 INCHES MINIMUM AND 0.330 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND, SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEFK | MAXIMUM STARTING TORQUE | 8.00 INCH-OUNCES |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.890 INCHES MINIMUM AND 0.910 INCHES MAXIMUM |
AGTP | LATERAL DISTANCE BETWEEN MOUNTING HOLE CENTERS | 0.890 INCHES MINIMUM AND 0.910 INCHES MAXIMUM |
APXH | TERMINAL LOCATION | REAR END |
AXGY | MOUNTING METHOD | TERMINAL |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.0 KILOHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.290 INCHES MINIMUM AND 0.310 INCHES MAXIMUM |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -250.0/+250.0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.75 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-22097 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
TTQY | TERMINAL TYPE AND QUANTITY | 3 WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-22097/2 GOVERNMENT SPECIFICATION |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
Remember Us the Next Time You’re Looking for NSN Parts. We Can Get You Some of the Quickest and Most Competitive Quotes In the Industry.
Request for Quote