NSN 5915-01-262-5886 Filter Radio Frequency Interfere manufactured by Rfi Corporation, Mtk Electronics Inc, Lindgren Rf Enclosures Inc, Litton Systems Inc, Spectrum Control Inc is available within ASAP Part Service’s ready-to-ship inventory. Owned and operated by ASAP Semiconductor, ASAP Part Services has over 6 billion parts within its inventory including 10907-4, 2141-040. ASAP is committed to streamlining the parts procurement process for our customers. We make it easy for our customers to search through billions of parts to find the exact part they are looking for.
A dedicated ASAP account manager is ready to help solve any procurement issues or needs that a customer may have. As a company we are quick and responsive meaning we can deliver a part within an AOG timeframe. Quality control is at the center of all that we do. Each and every NSN 5915-01-262-5886 part is subject to numerous quality checks that are designed to screen out any part imperfections or validity issues. Subject a request for quote for NSN 5915-01-262-5886 part today and allow us to simplify your procurement process.
Alternative NSN: 5915-01-262-5886 |
Item Name:Filter Radio Frequency Interfere |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5915 Filters and Networks |
NCB Code: USA (01) |
Manufacturers: Rfi Corporation , Mtk Electronics Inc , Lindgren Rf Enclosures Inc , Litton Systems Inc , Spectrum Control Inc |
Rfi Corporation | Mtk Electronics Inc | Lindgren Rf Enclosures Inc |
Litton Systems Inc | Spectrum Control Inc |
Part No Part No
|
Manufacturer NSN Parts
|
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
10907-4 | Rfi Corporation | filter radio frequency interfere | Avl | RFQ |
10907-4 | Mtk Electronics Inc | filter radio frequency interfere | Avl | RFQ |
10907-4 | Lindgren Rf Enclosures Inc | filter radio frequency interfere | Avl | RFQ |
10907-4 | Litton Systems Inc | filter radio frequency interfere | Avl | RFQ |
2141-040 | Litton Systems Inc | filter radio frequency interfere | Avl | RFQ |
2141-040 | Lindgren Rf Enclosures Inc | filter radio frequency interfere | Avl | RFQ |
2141-040 | Mtk Electronics Inc | filter radio frequency interfere | Avl | RFQ |
2141-040 | Spectrum Control Inc | filter radio frequency interfere | Avl | RFQ |
7117828-4 | Mtk Electronics Inc | filter radio frequency interfere | Avl | RFQ |
7117828-4 | Litton Systems Inc | filter radio frequency interfere | Avl | RFQ |
7117828-4 | Lindgren Rf Enclosures Inc | filter radio frequency interfere | Avl | RFQ |
E-1825 | Lindgren Rf Enclosures Inc | filter radio frequency interfere | Avl | RFQ |
M1686 | Mtk Electronics Inc | filter radio frequency interfere | Avl | RFQ |
M1686 | Lindgren Rf Enclosures Inc | filter radio frequency interfere | Avl | RFQ |
M1686 | Litton Systems Inc | filter radio frequency interfere | Avl | RFQ |
RF10907-4 | Rfi Corporation | filter radio frequency interfere | Avl | RFQ |
RF10907-4 | Mtk Electronics Inc | filter radio frequency interfere | Avl | RFQ |
RF10907-4 | Litton Systems Inc | filter radio frequency interfere | Avl | RFQ |
RF10907-4 | Lindgren Rf Enclosures Inc | filter radio frequency interfere | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.230 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.220 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.535 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.870 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.870 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 5TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 6TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 5TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 6TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
AHCG | MAXIMUM TEMP RISE | 25.0 DEG CELSIUS |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB, SOLDER LUG GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 7 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES |
CQRG | BODY MATERIAL | METAL |
CRST | BODY SURFACE TREATMENT | TIN |
FEAT | SPECIAL FEATURES | SEVEN FILTERED FUNCTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
Remember Us the Next Time You’re Looking for NSN Parts. We Can Get You Some of the Quickest and Most Competitive Quotes In the Industry.
Request for Quote