NSN 5945-00-889-0962 Relay Electromagnetic, Relay Electromagnet manufactured by Eaton Corp, Drs Power And Control Technologies is available within ASAP Part Service’s ready-to-ship inventory. Owned and operated by ASAP Semiconductor, ASAP Part Services has over 6 billion parts within its inventory including 6042H144, MIL-PRF-6106, MIL-R-6106. ASAP is committed to streamlining the parts procurement process for our customers. We make it easy for our customers to search through billions of parts to find the exact part they are looking for.
A dedicated ASAP account manager is ready to help solve any procurement issues or needs that a customer may have. As a company we are quick and responsive meaning we can deliver a part within an AOG timeframe. Quality control is at the center of all that we do. Each and every NSN 5945-00-889-0962 part is subject to numerous quality checks that are designed to screen out any part imperfections or validity issues. Subject a request for quote for NSN 5945-00-889-0962 part today and allow us to simplify your procurement process.
Alternative NSN: 5945-00-889-0962 |
Item Name:Relay Electromagnetic |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5945 Relays and Solenoids |
NCB Code: USA (00) |
Manufacturers: Eaton Corp , Drs Power And Control Technologies |
Part No Part No
|
Manufacturer NSN Parts
|
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
6042H144 | Eaton Corp | relay electromagnetic | Avl | RFQ |
6042H144 | Drs Power And Control Technologies | relay electromagnetic | Avl | RFQ |
MIL-PRF-6106 | Drs Power And Control Technologies | relay electromagnetic | Avl | RFQ |
MIL-PRF-6106 | Eaton Corp | relay electromagnet | Avl | RFQ |
MIL-R-6106 | Eaton Corp | relay electromagnet | Avl | RFQ |
MIL-R-6106 | Drs Power And Control Technologies | relay electromagnetic | Avl | RFQ |
MS24143-A2 | Eaton Corp | relay electromagnet | Avl | RFQ |
MS24143-A2 | Drs Power And Control Technologies | relay electromagnetic | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.700 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.887 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.576 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 3.305 INCHES MAXIMUM |
ADTV | CASE MATERIAL | METAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBME | III CUBIC MEASURE | 55.597 CUBIC INCHES |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
CRXH | TIME DELAY | 0.03 SECONDS MAXIMUM FIXED OPERATE TIME |
CRXH | TIME DELAY | 0.065 SECONDS MAXIMUM FIXED RELEASE TIME |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION AND 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC INDUCTIVE LOAD AND 25.0 AMPERES DC INDUCTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC MOTOR LOAD AND 25.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD AND 5.0 AMPERES DC INDUCTIVE LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 750.0 MILLIAMPERES AC LAMP LOAD AND 750.0 MILLIAMPERES DC LAMP LOAD |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTIN |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD ALL FUNCTIONS |
ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS24143 GOVERNMENT STANDARD |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
Remember Us the Next Time You’re Looking for NSN Parts. We Can Get You Some of the Quickest and Most Competitive Quotes In the Industry.
Request for Quote