ASAP Part Services, owned and operated by ASAP Semiconductor, has over 6 billion parts inventoried. This includes new, old, used, and obsolete parts, such as 0057000100, 04-0757, 04-0757, 04-1547, 04J48-20. As an ISO 9001:2015 certified and FAA AC 00-56B accredited company, we go to great lengths to ensure we are delivering quality parts. We partner exclusively with reliable manufacturers such as Werfen Usa Llc, Abbott Laboratories Inc, I Stat Corporation, Nova Biomedical Corp, Mallinckrodt Inc. Our team provides superior quality assurance testing for and more. So if you are in need of Analyzer Blood Gas or any other NSN parts, submit an Instant RFQ and receive a quote in as little as 15 minutes.
Part No Part No
|
NSN NSN Parts
|
Details Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
0057000100 | 6630-01-563-0430 | Special Features: 30.5 W X 30.7 D X 43.2 H Inches. Weight 13.4 Lbs. Universal Power Input 90-264 Vac, 50-60 Hertz, Sixty Minute Power Interrupt. Electrode Chamber Maintained At 37 Degree C Nominal. Data Output 3Rs-232 Serial I/O Ports, 1 Parallel Printer Port, 1 Ethernet Port. Sample Type; Whole Blood With Addtion Of Approx. 25 Usp Units/Ml Sodium Heparin Or Lithium Heparin. Response Time 85 Seconds From Sample Introduction Current Type: Ac Width: 21.600 Inches | Avl | RFQ |
04-0757 | 6630-01-520-5212 | Special Features: Uses One Platform To Perform Glucose Strip Testing; Handheld And Portable; True Point-Of-Care Testing; Rapid Test Results Part Name Assigned By Controlling Agency: Analyzer F/Chemistry-Blood Tests Handheld Test Type For Which Designed: Glucose; Blood Gas, Basic Chemistries, Cardiac And Coagulation | Avl | RFQ |
04-0757 | 6630-01-520-5212 | Special Features: Uses One Platform To Perform Glucose Strip Testing; Handheld And Portable; True Point-Of-Care Testing; Rapid Test Results Part Name Assigned By Controlling Agency: Analyzer F/Chemistry-Blood Tests Handheld Test Type For Which Designed: Glucose; Blood Gas, Basic Chemistries, Cardiac And Coagulation | Avl | RFQ |
04-1547 | 6630-01-526-7377 | Special Features: Blood Analyzer (I-Stat One) W/Hard Case; Package With Start-Up Supplies; A Field Kit Which Includes The Analyzer-One And, Supplies: C/O: 6640-01-519-5698, Motor System (Pn Md 10); 6630-01-526-4098, Battery, Rechargeable (Pn 06F23-55); 6630-01-422-2097, Simulator, Quality Control Test (Pn 06F11-01); 6630-01-526-4091, Printer, Portable (06F23-91); 6630-01-524-3128, Cartridge, Ceramic (Pn 04J51-01); 6630-01-487-8551, Guard, Mechanical, Drive (Pn 6509E85-003); 6630-01-526-3620, Downloader-Recharger Unit (Pn 06F23-45); 6630-01-526-4102, Carry Case (Pn 06F16-79); And 6135-01-421-7168, Battery, Nonrechargeable (Pn 6F2126). Part Name Assigned By Controlling Agency: I-Stat 1 Government Field Kit | Avl | RFQ |
04J48-20 | 6630-01-526-7377 | Special Features: Blood Analyzer (I-Stat One) W/Hard Case; Package With Start-Up Supplies; A Field Kit Which Includes The Analyzer-One And, Supplies: C/O: 6640-01-519-5698, Motor System (Pn Md 10); 6630-01-526-4098, Battery, Rechargeable (Pn 06F23-55); 6630-01-422-2097, Simulator, Quality Control Test (Pn 06F11-01); 6630-01-526-4091, Printer, Portable (06F23-91); 6630-01-524-3128, Cartridge, Ceramic (Pn 04J51-01); 6630-01-487-8551, Guard, Mechanical, Drive (Pn 6509E85-003); 6630-01-526-3620, Downloader-Recharger Unit (Pn 06F23-45); 6630-01-526-4102, Carry Case (Pn 06F16-79); And 6135-01-421-7168, Battery, Nonrechargeable (Pn 6F2126). Part Name Assigned By Controlling Agency: I-Stat 1 Government Field Kit | Avl | RFQ |
04P75-01 | 6630-01-597-6733 | Special Features: Point-Of-Use Analyzer For Measurement Of Blood Gases And Electrolytes (Without Glucose Test Strip Port); Requires No Sample Prep; Weight: Approx. 18 Oz; Operator Lockout Prevents Unauthorized Users From Performing Or Viewing Test Results; Self Calibration; Uses Test Cartridges Part Name Assigned By Controlling Agency: Analyzer Blood Gas I-Stat | Avl | RFQ |
06F16-10 | 6630-01-520-5212 | Special Features: Uses One Platform To Perform Glucose Strip Testing; Handheld And Portable; True Point-Of-Care Testing; Rapid Test Results Part Name Assigned By Controlling Agency: Analyzer F/Chemistry-Blood Tests Handheld Test Type For Which Designed: Glucose; Blood Gas, Basic Chemistries, Cardiac And Coagulation | Avl | RFQ |
06F16-10 | 6630-01-532-3726 | Special Features: Uses One Platform To Perform Glucose Strip Testing; Handheld And Portable; True Point-Of-Care Testing; Rapid Test Results Part Name Assigned By Controlling Agency: Analyzer F/Chemistry-Blood Tests Handheld Test Type For Which Designed: Glucose; Blood Gas, Basic Chemistries, Cardiac And Coagulation | Avl | RFQ |
06F16-10 | 6630-01-520-5212 | Special Features: Uses One Platform To Perform Glucose Strip Testing; Handheld And Portable; True Point-Of-Care Testing; Rapid Test Results Part Name Assigned By Controlling Agency: Analyzer F/Chemistry-Blood Tests Handheld Test Type For Which Designed: Glucose; Blood Gas, Basic Chemistries, Cardiac And Coagulation | Avl | RFQ |
113S2 | 6630-00-143-6763 | Special Features: Design Type:Auxiliary Unit Constructed;Scale Range:P10.0/P100.0 Millimeters And P0.0/P800.0 Millimeters;Measuring Method:Manometric;Electrical Shaking Device:Not Provided;Auxiliary Unit Name And Qty:Constant Temp Bath-1, Electrode, Hydrogen Ion, Glass-2, Electrode Assy, Pco2-2 Assy, Po2-2, Electrolyte, Pco-1 Bottle, Electrolyte, Po2-1 Bottle, Carbon Dioxide- Oxygen-1, Nitrogen-Carbon Dioxide 1, Parts Kit, Pco2 Membrane-1, Parts Kit Po2.Membrane-1, Std Solution Buffer, 6.84 Ph-1 Bottle, Std Solution Buffer 7.384 Ph-1 Bottle Regulator-1, Glass Cylinder;Used For Micro Determinations Of Ph Pco2 And Po2; Unit Of Issue Cube: 4.564 Cubic Feet Unit Of Issue Weight: 56.00 Pounds | Avl | RFQ |
1304 W PROVISIONING | 6630-01-304-2167 | Special Features: 200 Watts; Automatic; Microprocessor; C/O A Self-Contained Electronic Blood Ph/Gas Analyzer System, Measuring Ph, Pco2, And Po2, And Computing Bicarbonate, Total Co2 And Base Excess; Accommodates Two Sample Size; 175 Microliters Or Less Capillary And 500 Microliters Or Less Syringe; Complete W/Supplies Necessary For Operation; For Control Set, Order 6550011197680; For Replacement Reagents And Consumables Order The Following; 6550002824025 Buffer Sol; 6550002833206 Buffer Sol; 6830002809240 Calibrating Gas Mix; 6830010500117 Cal Gas Mix; 6630011669527 Clean Compound Bga; 6630011488966 Deprotienizing Sol; 6630011667775 Electrode, Pco2 And Membrane Kit; 6630011687853 Electrode; Ph Bga; 6630011667773 Electrode, Po2 And Membrane Kit; 6630011631625 Filling Sol Electrode; 6630011631626 Filling Sol Electrode Part Name Assigned By Controlling Agency: Analyzer Blood Gas Volumetric 120/230V 50/60Hz Ac Current Type: Ac | Avl | RFQ |
25498 | 6630-01-597-6733 | Special Features: Point-Of-Use Analyzer For Measurement Of Blood Gases And Electrolytes (Without Glucose Test Strip Port); Requires No Sample Prep; Weight: Approx. 18 Oz; Operator Lockout Prevents Unauthorized Users From Performing Or Viewing Test Results; Self Calibration; Uses Test Cartridges Part Name Assigned By Controlling Agency: Analyzer Blood Gas I-Stat | Avl | RFQ |
27813 | 6630-01-540-1606 | Part Name Assigned By Controlling Agency: Calcium Sensor Phox Plus | Avl | RFQ |
4300M | 6630-01-364-8555 | Special Features: Utilizes A Disposable Cartridge/Test Pack That Contains All Electrodes, Calibrating Solutions And Gases Plus A Waste Bag For Processed Blood, Calibrating And Qc Solutions. The Cartridge/Test Pack Shall Eliminate The Need For Gas Tanks External Solutions, And Electrode Maintenance. Shall Be Pre-Programed To Automatically Perform Two-Point Calibrations Every Hour And One-Point Calibrations Every 90 Seconds. Capable Of Automatic Aspiration Of The Sample And To Process, Display, And Print The Results In Less Than 2 Minutes. Shall Be Suitable For The Field Environment. Part Name Assigned By Controlling Agency: Blood Gas Analyzer 120/230V 50/60 Hz Ac: Current Type: Ac | Avl | RFQ |
4300M W PROVISIONING | 6630-01-364-8555 | Special Features: Utilizes A Disposable Cartridge/Test Pack That Contains All Electrodes, Calibrating Solutions And Gases Plus A Waste Bag For Processed Blood, Calibrating And Qc Solutions. The Cartridge/Test Pack Shall Eliminate The Need For Gas Tanks External Solutions, And Electrode Maintenance. Shall Be Pre-Programed To Automatically Perform Two-Point Calibrations Every Hour And One-Point Calibrations Every 90 Seconds. Capable Of Automatic Aspiration Of The Sample And To Process, Display, And Print The Results In Less Than 2 Minutes. Shall Be Suitable For The Field Environment. Part Name Assigned By Controlling Agency: Blood Gas Analyzer 120/230V 50/60 Hz Ac: Current Type: Ac | Avl | RFQ |
475028 | 6630-01-063-2944 | Special Features: Semi-Automatic W/Calibrating Gas Kit, Capable Of Measuring Ph, Pc02;P02 And Calculates Bicarbonate, Hc03;Total C02 And Base Excess, Minimal Ranges, Ph6.0 To 8.0;Pc02, 0.0 To 200.0 Mmhg;P02 1.0 To 200.0 Mmhg;Total C02, 0 To 100 Mm/L;Hc03, 0 To 100 Mm/L And Base Excess, P40 To M40 Meq/L;Samples Sizes 250 Ul And 500 Ul;Built-In Sample Chamber Flush System Current Type: Ac Voltage In Volts: 115.0 | Avl | RFQ |
475280 | 6630-01-314-4292 | Special Features: Automatic; C/O Electrodes, Reagents, Initial Calibration And Supplies Necessary For Start Up Operation; Calculates And Measures Ph, Po2 And Base Excess; Bicarbonate And 02 Saturation; Permits The Introduction Of Samples Of Venous Blood, Arterial Blood And Expired Gas Part Name Assigned By Controlling Agency: Analyzer Blood Gas Volumetric 115/230V 50/60Hz Single Phase Auto Current Type: Ac | Avl | RFQ |
475435 | 6630-01-314-4292 | Special Features: Automatic; C/O Electrodes, Reagents, Initial Calibration And Supplies Necessary For Start Up Operation; Calculates And Measures Ph, Po2 And Base Excess; Bicarbonate And 02 Saturation; Permits The Introduction Of Samples Of Venous Blood, Arterial Blood And Expired Gas Part Name Assigned By Controlling Agency: Analyzer Blood Gas Volumetric 115/230V 50/60Hz Single Phase Auto Current Type: Ac | Avl | RFQ |
6630-0284-0000 | 6630-01-304-2167 | Special Features: 200 Watts; Automatic; Microprocessor; C/O A Self-Contained Electronic Blood Ph/Gas Analyzer System, Measuring Ph, Pco2, And Po2, And Computing Bicarbonate, Total Co2 And Base Excess; Accommodates Two Sample Size; 175 Microliters Or Less Capillary And 500 Microliters Or Less Syringe; Complete W/Supplies Necessary For Operation; For Control Set, Order 6550011197680; For Replacement Reagents And Consumables Order The Following; 6550002824025 Buffer Sol; 6550002833206 Buffer Sol; 6830002809240 Calibrating Gas Mix; 6830010500117 Cal Gas Mix; 6630011669527 Clean Compound Bga; 6630011488966 Deprotienizing Sol; 6630011667775 Electrode, Pco2 And Membrane Kit; 6630011687853 Electrode; Ph Bga; 6630011667773 Electrode, Po2 And Membrane Kit; 6630011631625 Filling Sol Electrode; 6630011631626 Filling Sol Electrode Part Name Assigned By Controlling Agency: Analyzer Blood Gas Volumetric 120/230V 50/60Hz Ac Current Type: Ac | Avl | RFQ |
6630-0285-0000 | 6630-01-063-2944 | Special Features: Semi-Automatic W/Calibrating Gas Kit, Capable Of Measuring Ph, Pc02;P02 And Calculates Bicarbonate, Hc03;Total C02 And Base Excess, Minimal Ranges, Ph6.0 To 8.0;Pc02, 0.0 To 200.0 Mmhg;P02 1.0 To 200.0 Mmhg;Total C02, 0 To 100 Mm/L;Hc03, 0 To 100 Mm/L And Base Excess, P40 To M40 Meq/L;Samples Sizes 250 Ul And 500 Ul;Built-In Sample Chamber Flush System Current Type: Ac Voltage In Volts: 115.0 | Avl | RFQ |
6630NCM116485 | 6630-01-597-6733 | Special Features: Point-Of-Use Analyzer For Measurement Of Blood Gases And Electrolytes (Without Glucose Test Strip Port); Requires No Sample Prep; Weight: Approx. 18 Oz; Operator Lockout Prevents Unauthorized Users From Performing Or Viewing Test Results; Self Calibration; Uses Test Cartridges Part Name Assigned By Controlling Agency: Analyzer Blood Gas I-Stat | Avl | RFQ |
6F16-05 | 6630-01-580-8302 | NA | Avl | RFQ |
ACCESS 2 | 6630-01-522-9835 | Special Features: Immunology Instrument; Blood Analyzer | Avl | RFQ |
AVL 990 AVL 990-S | 6630-01-528-9109 | Part Name Assigned By Controlling Agency: Analyzer Blood Gas Model: Avl 990/Avl 990-S | Avl | RFQ |
F-268 | 6630-01-034-0480 | Special Features: C/0 A Self-Contained Electronic Blood Ph/Gas Analyzer System Measuring Ph, Pc02, P02 And Computing Plasma Bicarbonate, Base Excess, Oxygen Saturation, Oxygen Content And Total Carbon Dioxide Content, Automatic Single Point Calibration Every 30 Min And Two Point Calibration Every Two Hours, Two Sample Sizes 130 And 500 Microliters, Ph Range 6.5O To 8;Manometric Measuring Part Name Assigned By Controlling Agency: Analyzer Bld Gas 500Watts Complete W/Supplies Necessary F/Oper Unit Of Issue Cube: 58.000 Cubic Feet | Avl | RFQ |
GD7006 | 6630-01-459-0640 | Special Features: Fluorescence, Reflectance Features Provided: Batch Processing And Digital Display Screen And Integral Autosampling System And Integral Printer And Self-Calibration Method Of Analysis: Fluorometric | Avl | RFQ |
GEM PREMIER 3000 | 6630-01-563-0430 | Special Features: 30.5 W X 30.7 D X 43.2 H Inches. Weight 13.4 Lbs. Universal Power Input 90-264 Vac, 50-60 Hertz, Sixty Minute Power Interrupt. Electrode Chamber Maintained At 37 Degree C Nominal. Data Output 3Rs-232 Serial I/O Ports, 1 Parallel Printer Port, 1 Ethernet Port. Sample Type; Whole Blood With Addtion Of Approx. 25 Usp Units/Ml Sodium Heparin Or Lithium Heparin. Response Time 85 Seconds From Sample Introduction Current Type: Ac Width: 21.600 Inches | Avl | RFQ |
I-STAT-1 ANALYZER | 6630-01-520-5212 | Special Features: Uses One Platform To Perform Glucose Strip Testing; Handheld And Portable; True Point-Of-Care Testing; Rapid Test Results Part Name Assigned By Controlling Agency: Analyzer F/Chemistry-Blood Tests Handheld Test Type For Which Designed: Glucose; Blood Gas, Basic Chemistries, Cardiac And Coagulation | Avl | RFQ |
I-STAT-1 ANALYZER | 6630-01-520-5212 | Special Features: Uses One Platform To Perform Glucose Strip Testing; Handheld And Portable; True Point-Of-Care Testing; Rapid Test Results Part Name Assigned By Controlling Agency: Analyzer F/Chemistry-Blood Tests Handheld Test Type For Which Designed: Glucose; Blood Gas, Basic Chemistries, Cardiac And Coagulation | Avl | RFQ |
IBM PS 2 MODEL 35SX | 6630-01-368-2880 | Special Features: Automatic; C/O Electrodes, Reagents, Inital Calibration And Supplies Necessary For Start Up Operation; Calculates And Measures Ph, Po2 And Base Excess, Bicarbonate, And O2 Saturation; Permits The Introduction Of Samples Of Venous Blood, Arterial Blood; And Expired Gas Part Name Assigned By Controlling Agency: Analyzer Blood Gas 115/230V 50/60Hz Ac Current Type: Ac | Avl | RFQ |
IL713 | 6630-01-109-4708 | Special Features: 18 To 30 Deg Cent.Operate; Voltage In Volts: 115.0 Frequency Rating: 60.0 Hertz Nominal | Avl | RFQ |
LL-H37-4333 | 6630-01-528-9109 | Part Name Assigned By Controlling Agency: Analyzer Blood Gas Model: Avl 990/Avl 990-S | Avl | RFQ |
LL-H44-8964 | 6630-01-530-2177 | Part Name Assigned By Controlling Agency: Analyzer Blood Gas Model: 238 | Avl | RFQ |
LL-H46-2724 | 6630-01-522-2869 | End Item Identification: Analyzer Blood Gas Model 278 | Avl | RFQ |
M1190A | 6630-01-445-7991 | NA | Avl | RFQ |
M1190A | 6630-01-445-7991 | NA | Avl | RFQ |
MODEL 278 W DATAMATE | 6630-01-368-2880 | NA | Avl | RFQ |
N0-059 | 6630-01-364-8555 | Special Features: Utilizes A Disposable Cartridge/Test Pack That Contains All Electrodes, Calibrating Solutions And Gases Plus A Waste Bag For Processed Blood, Calibrating And Qc Solutions. The Cartridge/Test Pack Shall Eliminate The Need For Gas Tanks External Solutions, And Electrode Maintenance. Shall Be Pre-Programed To Automatically Perform Two-Point Calibrations Every Hour And One-Point Calibrations Every 90 Seconds. Capable Of Automatic Aspiration Of The Sample And To Process, Display, And Print The Results In Less Than 2 Minutes. Shall Be Suitable For The Field Environment. Part Name Assigned By Controlling Agency: Blood Gas Analyzer 120/230V 50/60 Hz Ac: Current Type: Ac | Avl | RFQ |
NOVA STAT PROFILE 2 | 6630-01-343-6767 | NA | Avl | RFQ |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
Remember Us the Next Time You’re Looking for NSN Parts. We Can Get You Some of the Quickest and Most Competitive Quotes In the Industry.
Request for Quote