ASAP Part Services, owned and operated by ASAP Semiconductor, has over 6 billion parts inventoried. This includes new, old, used, and obsolete parts, such as 00-004100-00, 00-144010-00 60 HZ, 00-144020-00 60 HZ, 00-210020-01, 00-274010-00. As an ISO 9001:2015 certified and FAA AC 00-56B accredited company, we go to great lengths to ensure we are delivering quality parts. We partner exclusively with reliable manufacturers such as Communications And Power Industrie, Applied Biosystems Llc, Agilent Technologies Inc, British Sarozal Ltd, Abb Inc. Our team provides superior quality assurance testing for and more. So if you are in need of Chromatograph Gas or any other NSN parts, submit an Instant RFQ and receive a quote in as little as 15 minutes.
Communications And Power Industrie | Applied Biosystems Llc | Agilent Technologies Inc |
British Sarozal Ltd | Abb Inc |
Part No Part No
|
NSN NSN Parts
|
Details Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
00-004100-00 | 6630-01-016-0412 | General Characteristics Item Description: Liquid Chromatograph, 250 Ml Solvent Capacity, 0 To 5000 Psi Presure Range 0 To 200 Ml/Hr Variable Flow Rate Stainless Steel And Polytetrafluoroethylene Constuction, 115/230 Vac, 50/60 Hz, 250 Watt, High Pressure Injector, 7 Gal Capacity Water Bath, 70 Deg C Max Temp, Varian Aerograph Model A-25 Recorder Included In Assembly, 20 Chart Speeds, 1Mv To 1 V Selectable Span | Avl | RFQ |
00-144010-00 60 HZ | 6630-01-012-7063 | General Characteristics Item Description: Single Column Flame Ionization Detector, Linear Temp Programmer, Cools From 400 Deg C To 40 Deg C In 6 To 8 Min., 0.0000000000009 G/Sec Detectability, 0.01 Coulomb/G Sensitivity, Solid State Electrometer Circuitry 0.000000000001 A/Mv Sensitivity, Univers Carrier Gas System, Column Oven Stainless Steel Construction, 9.0 In. By 4.5 In. By 10.0 In., 405 Cu. In., Isothermal Mode Temp Control, Direct Dialing And Readout Of Temp, Porm 0.5 Deg C Stability, 115 Vac, 60 Hz, 1200 W, 0/A Dimensions 16.0 In. By 16.5 In. By 16.0 In. | Avl | RFQ |
00-144020-00 60 HZ | 6630-01-061-3642 | General Characteristics Item Description: Single Column Flame Ionization Detector, Isothermal Proportional Oven Temperature Controller; Column Oven Cools From 400-40 Deg C In 6-8 Min., Statnless Steel, Internal Centrifugal Blower, 9 In. W, 4.5 In. H, 10 In. D; Universal Carrier Gas System; Thermocouple Pyrometer; Packed Column Injector; 115 Vac, 60 Hz, 1200 W; 0/A Dimensions 16 In. W, 16.5 In. H, 16 In. D | Avl | RFQ |
00-210020-01 | 6630-01-034-0450 | General Characteristics Item Description: 4 U-Shaped Columns, 4 Detector Bases, 4 Injectors, 1 Dual/Differential Electrometer, 4 Rotameters And Flow Controllers, Linear Programmer; 230 Vac, 50/60 Hz; Column Oven 11 In. W, 38 In. H, 7 In. D, 3000 Cu. In. Volume, Temp Range Ambient To 400 Deg C With Readout, Cooling Rate 400 To 100 Deg C In 5 Min. | Avl | RFQ |
00-274010-00 | 6630-01-013-8773 | General Characteristics Item Description: Dual Column, Dual Ionization, Modular, Hydrogen Flame Ionization Detector, 0.01 Coulomb/G Sensitivity, 400 Deg C Temp Limit, Cast Aluminum Detector Oven, Stability W/In 0.5 Deg C Of Ambient Up To 400 Deg C, 1090 Cu. In. Column Oven, Stainless Steel, 400 To 100 Deg C W/In 3 Min. Cooling Rate, Linear Temp Programmer, Isothermal Mode, Rate Range 0.5 To 20.0 Deg C/Min., 115 Vac Operation, 19.5 In. Dp, 21.815 In. Hg, 21.5 In. Lg | Avl | RFQ |
00-371114-00 | 6630-01-065-0502 | General Characteristics Item Description: Automatic, For Ionization Detectors, Digital Readout, 2 Digital Oven Temp Controllers, 1 Detector, 2 Universal Ionization Detector Bases, 2 Pressure Gages; 120 Vac, 50/60 Hz | Avl | RFQ |
00-374000-00 | 6630-01-070-5149 | General Characteristics Item Description: Column Oven 25 Cm H, 38 Cm W, 23 Cm D; 2 Digital Oven Temp Controllers For Injectors, Digital Readout, Digital Oven Temp Controller For Detectors, 2 Pressure Gages; 115 Vac, 50/60 Hz | Avl | RFQ |
00-374000-00 1040 1070 2010 601 | 6630-01-073-0604 | NA | Avl | RFQ |
00-376000-00 | 6630-01-113-1951 | General Characteristics Item Description: All-Glass Capillary System, Cool Injector Septum Holder, Extra Large Column Oven-1350 Cubic In. W/Removable Door, Automatic Linear Temperature Programmer, Flame Ionization Detector, Column Oven Size 10 In. H, 15 In. W, 9 In. D, Temp Range 12 Deg C Above Ambient To 420 Deg C, Heat-Up Time 50 To 400 Deg C In 12 Min At Nominal Line Voltage Of 120 Vac | Avl | RFQ |
00-400000-00 | 6630-01-071-5593 | General Characteristics Item Description: 1000 Psi Pump, Pump Stand, Reservoir Capacity 500 Ml Max, Stainless Steel Injector W/Silicone Rubber Septum, Micropak Column, Operating Manual | Avl | RFQ |
00-502000-00 | 6630-01-082-0425 | General Characteristics Item Description: Microcomputer-Based Interactive Crt-Keyboard Control, 9 Method Memory; Flow Rate 0.0-15 Ml/Min In 0.1 Ml/Min Increments, Operating Pressure 0-5000 Psi; Enclosed Compartment For Three 1 Gal Solvent Bottles; Flow And Gradient Programming; Column Temp Control Ambient To 140 Deg C In 1 Deg C Increments; 100/110/120 Vac, 60 Hz, 200/220/240 Vac, 50 Hz, 1 Kw Minimum; 31 In. W, 20 In. H, 20 In. D | Avl | RFQ |
00-503100-00 | 6630-01-080-1968 | General Characteristics Item Description: Gradient Liquid W/Microcomputer-Based Interactive Crt-Keyboard Control;W/Upper And Lower Pressure Limits; Enclosed Compartment For Three 1 Gal Solvent Bottles; 100, 110, Or 120V Ac, 60 Hz. Or 200, 220, Or 240 V Ac, 50 Hz., 1000 Watts Min, 31 In. W, 20 In. H, 20 In. Depth; Stainless Steel And Polytetrafluoroethylene End Item Identification: Gradient Automatic Liquid Chromatograph Model 5021 | Avl | RFQ |
00-851000-00 | 6630-01-066-8070 | General Characteristics Item Description: Max Flow Rate 990 Ml/Hr, Max Pressure 8500 Psi, 250 Ml Syringe Pump; Selectable Operating Voltage 100, 115, 130, 200, 227, 240 Vac Porm 10 Pct., 50/60 Hz; 16.75 In. W, 16.75 In. D, 32 In. H | Avl | RFQ |
009-0962 | 6630-00-585-2427 | General Characteristics Item Description: 117 V, 60 Hz, Single Channel, Dual Flame Ionization, Temperature Programmed | Avl | RFQ |
0254-0297 | 6630-01-151-6742 | General Characteristics Item Description: Jpower Reqs, 100-125Vac; 60 Hz; C/Olc-85B Uv Detector, P/N 0271-0071; Ls-4Fluorescence Detector, P/N 5212-4601; Lc-25 Refractive Index Detector, P/N 0271-0218; Chromatographics 2 Data System, P/N N335-0087; Complete | Avl | RFQ |
0331-9100 0331-0006 0331-4004 0 | 6630-01-063-7267 | General Characteristics Item Description: 117 Vac, 50/60 Hz, Consists Of 9 Detectors, 1 Amplifier, 1 Control Console, 1 Column Oven, Oven Capacity 10, 000 Cm Reference Number Differentiating Characteristics: As Differentiated By An Extra Long Refeence Number Extra Long Reference Number: 0331-9100/0331-0006/0331-4004/0331-3115/0331-8280/0331-2201/0331-1000/0332-0118 | Avl | RFQ |
0331-9730 | 6630-01-196-3501 | NA | Avl | RFQ |
1072 | 6630-01-064-3407 | NA | Avl | RFQ |
1420 | 6630-00-519-1000 | General Characteristics Item Description: Dual Column, Independent Flow Controllers, Highly Regulated Solid State Bridge Power Supply, 3 Solid State Column Oven Temperature Controllers | Avl | RFQ |
144510-00 | 6630-00-519-1017 | General Characteristics Item Description: Single Column, 1/4 In. Glass, Flame Ionization Detector, Linear Programmer, 115 Volt, 50 To 60 Hertz | Avl | RFQ |
1704A01257 | 6630-01-051-4798 | General Characteristics Item Description: Has Digital Processor Which Controls All Aspects Of The Gc Analysis; All Temp. Carrier Flow Rate Measurement, Detector Operation, Integration Of Peak Areas, Identification Of Component, Calculation Of Concentrations, Plotting Of Chromatogram And Analysis Report, Universal Injection Port, Multi-Purpose Glass Capillary Inlet System, Time Programming, Which Allows Change Throughout The Analysis, Run Programming, Has Capillary Column, Oven Which Can Be Controlled And Programmed From -60 Deg. To 400 Deg. C. | Avl | RFQ |
19199M | 6630-01-564-8814 | Part Name Assigned By Controlling Agency: Gcsupply Gas Installation Kit | Avl | RFQ |
220-1170 | 6630-01-546-5156 | Special Features: Measures All Non Corrosive Gases; Gages Flow Rates For Chromotograph; +/- 3 % Accuracy; .5 To 1000 Ml/Min Flow Rate; 0-45 Deg C Operating Temp; Operates On 1 9V Battery Part Name Assigned By Controlling Agency: Flowmeter Voltage In Volts And Current Type: 9.0 Dc | Avl | RFQ |
3000A | 6630-01-553-4216 | Special Features: Integrated W/Single Vendor System Configuration; Software Controlled Four Port Stream Selector Valve, Electronic Gas Controlled; Variable Injection Volume Of 1 Ul To 10 Ul W/Backflush Modules; Operates With A Maximum Injection Time 999 Msec; Heated Injector Up To 100 Deg C; Column Oven Temperature 30 Deg C To Plus 180 Deg C; Backflush Capabilities; Data Station Includes Software For Instrument Control And Data Processing, Computer W/Windows Xp Professional Sp2, 3.4 Ghz Pentium 4 Processor, 1.0 Gb Ram, 1.44 Mb Floppy Drive, 2 Pci Slots, 2 Serial Ports, 1 Parallel Port, 8 Usb 2.0 Ports And 17 Inch Flat Panel Display Screen | Avl | RFQ |
331-9100 | 6630-01-063-7267 | General Characteristics Item Description: 117 Vac, 50/60 Hz, Consists Of 9 Detectors, 1 Amplifier, 1 Control Console, 1 Column Oven, Oven Capacity 10, 000 Cm Reference Number Differentiating Characteristics: As Differentiated By An Extra Long Refeence Number Extra Long Reference Number: 0331-9100/0331-0006/0331-4004/0331-3115/0331-8280/0331-2201/0331-1000/0332-0118 | Avl | RFQ |
331-9200 331-0002 331-2442 331 | 6630-01-072-6186 | NA | Avl | RFQ |
3700 | 6630-01-070-5149 | General Characteristics Item Description: Column Oven 25 Cm H, 38 Cm W, 23 Cm D; 2 Digital Oven Temp Controllers For Injectors, Digital Readout, Digital Oven Temp Controller For Detectors, 2 Pressure Gages; 115 Vac, 50/60 Hz | Avl | RFQ |
3700 | 6630-01-073-0604 | General Characteristics Item Description: Column Oven 25 Cm H, 38 Cm W, 23 Cm D; 2 Digital Oven Temp Controllers For Injectors, Digital Readout, Digital Oven Temp Controller For Detectors, 2 Pressure Gages; 115 Vac, 50/60 Hz | Avl | RFQ |
3711 | 6630-01-065-0502 | General Characteristics Item Description: Automatic, For Ionization Detectors, Digital Readout, 2 Digital Oven Temp Controllers, 1 Detector, 2 Universal Ionization Detector Bases, 2 Pressure Gages; 120 Vac, 50/60 Hz | Avl | RFQ |
3760 | 6630-01-113-1951 | General Characteristics Item Description: All-Glass Capillary System, Cool Injector Septum Holder, Extra Large Column Oven-1350 Cubic In. W/Removable Door, Automatic Linear Temperature Programmer, Flame Ionization Detector, Column Oven Size 10 In. H, 15 In. W, 9 In. D, Temp Range 12 Deg C Above Ambient To 420 Deg C, Heat-Up Time 50 To 400 Deg C In 12 Min At Nominal Line Voltage Of 120 Vac | Avl | RFQ |
3920 | 6630-00-358-9474 | General Characteristics Item Description: Mc/O Flame Ionization Detectors W/Single Or Dual Channel Amplifiers, Hot Wire Detector, Electron Capture Detectors, Sample Injectors, Column Oven Temperature Control, Automated Sampling Systems, Elec Data, 115 V, 60 Hz, Ac | Avl | RFQ |
5020 | 6630-01-082-0425 | General Characteristics Item Description: Microcomputer-Based Interactive Crt-Keyboard Control, 9 Method Memory; Flow Rate 0.0-15 Ml/Min In 0.1 Ml/Min Increments, Operating Pressure 0-5000 Psi; Enclosed Compartment For Three 1 Gal Solvent Bottles; Flow And Gradient Programming; Column Temp Control Ambient To 140 Deg C In 1 Deg C Increments; 100/110/120 Vac, 60 Hz, 200/220/240 Vac, 50 Hz, 1 Kw Minimum; 31 In. W, 20 In. H, 20 In. D | Avl | RFQ |
5710A | 6630-01-055-2705 | General Characteristics Item Description: Column Oven-Double Wall-Capacity Max. 60 Ft. X 1/8 In. Od Or 30 Ft. Of 1/4 In. Od Columns, Temp Range -50 Deg C. To 399 Deg C., Temp Programmer-Auto Digital, Repeatability 0.1 Pct, Detector, Injector And Auxiliary Temp Controllers, Flame Ionization Detector-Dual Grounded Jet, Electrometer-Two Stage Bipolar Design, Output-Recorder 1Mv Full Scale With Binary Output Attenuator 1-1024, Computer-10V Per Scale, Thermal Conductivity Detector-Dual, Four Passivated Tungstenrhenium Filaments, Electron Capture Detector-Type-15 Mc Ni63source Plated Directly On Coaxial Chamber, Size-18.500 X 22.250 X 19.000, Power Consumption-1800 Va Max., 115-230V Plus Or Minus Single Or Split Phase, 48-66 Hz. | Avl | RFQ |
5734A | 6630-01-027-9052 | General Characteristics Item Description: Dual Column, Dual Input/Dual Output Electrometer, W/Option Po3, Main Power Cord Reference Number Differentiating Characteristics: As Differentiated By The Main Power Cord | Avl | RFQ |
5737A | 6630-01-044-4577 | General Characteristics Item Description: Dual Flame Ionization And Single Flame Photometric; Electrometer, Dual Carrier Gas Flow Controllers, Dual Universal Heated Injection Port, Digital Linear Oven Temp Programmer; 120 Vac, 60 Hz | Avl | RFQ |
5750 | 6630-01-059-1034 | NA | Avl | RFQ |
5750B | 6630-01-006-5954 | General Characteristics Item Description: Oven Heats From 50 To 400 Deg C In 10 Min, Temp Gradient Porm 1.0 Pc Max, Programmable Operation, No Detector Or Detector Controls Included, 105-125 Vac, 60 Hz | Avl | RFQ |
5831A | 6630-01-036-6553 | General Characteristics Item Description: Dual Flame Ionization; Dual Channel Flow Sensor, Thermal Paper Printer/Plotter, 108/126 Vac, 58/62 Hz; 125 V Power Cable; Liquid Nitrogen Coolant Cryogenic Oven; Dual Flame Ionization Detector Kit; Cryogenic Oven Kit For Operation To M50 Deg, Liquid Nitrogen Coolant; Auto Sampler For Use Only Under Keyboard Control; Air Sampler For 115 Vac Operation Reference Number Differentiating Characteristics: As Differentiated By Cryogenic Oven Kit, Auto Sampler, And Air Sampler Extra Long Reference Number: 5831A/P03/Option010/18812A/18810A/18824A/Option801 | Avl | RFQ |
5831A P03 OPTION010 18812A 1881 | 6630-01-036-6553 | General Characteristics Item Description: Dual Flame Ionization; Dual Channel Flow Sensor, Thermal Paper Printer/Plotter, 108/126 Vac, 58/62 Hz; 125 V Power Cable; Liquid Nitrogen Coolant Cryogenic Oven; Dual Flame Ionization Detector Kit; Cryogenic Oven Kit For Operation To M50 Deg, Liquid Nitrogen Coolant; Auto Sampler For Use Only Under Keyboard Control; Air Sampler For 115 Vac Operation Reference Number Differentiating Characteristics: As Differentiated By Cryogenic Oven Kit, Auto Sampler, And Air Sampler Extra Long Reference Number: 5831A/P03/Option010/18812A/18810A/18824A/Option801 | Avl | RFQ |
5840A | 6630-01-055-2704 | General Characteristics Item Description: It Has An Integral Digital Processor That Operates Throughout The Analytical Run, On An Easy-To-Use Key Board Or Magnetic Card Reader, A High-Performance Oven That Can Be Programmed And Controlled From A Minus 65 To Plus 400 Degrees Centigrade To Meet Seperation Requirements, You Can Control Oven Temperature A Few Degrees Above Ambient, As Low As 35 Degrees Centigrade W/O Using A Coolant, Two Detectors Are Accommodated Simultaneously, It Is Power Rated At 1800Va, Operates Between 100 And 250 Vac, 48 To 62 Hertz And On A 20 Amp Dedicated Circuit | Avl | RFQ |
5890 | 6630-01-227-4274 | General Characteristics Item Description: Range To 400 Deg C;Frequency 47.5-66 Hz; Consumption 2200 Va Max; Outout 7500 Btu/Hr Max; Up To 4 Heated Zones; Oven Temp. From 50 Deg To 400 Deg C; Height 17.250 In.; Width 23.750 In.;Depth 25.500 Inches; Wt 90 Lbs; Voltages 120/200/220/240; Usable Volume: 21.2 L, 1295 Cu Inches | Avl | RFQ |
5890A | 6630-01-255-6842 | General Characteristics Item Description: Range To 400 Deg C;Frequency 47.5-66 Hz; Consumption 2200 Va Max; Outout 7500 Btu/Hr Max; Up To 4 Heated Zones; Oven Temp. From 50 Deg To 400 Deg C; Height 17.250 In.; Width 23.750 In.;Depth 25.500 Inches; Wt 90 Lbs; Voltages 120/200/220/240; Usable Volume: 21.2 L, 1295 Cu Inches | Avl | RFQ |
5890A | 6630-01-227-4274 | General Characteristics Item Description: Range To 400 Deg C;Frequency 47.5-66 Hz; Consumption 2200 Va Max; Outout 7500 Btu/Hr Max; Up To 4 Heated Zones; Oven Temp. From 50 Deg To 400 Deg C; Height 17.250 In.; Width 23.750 In.;Depth 25.500 Inches; Wt 90 Lbs; Voltages 120/200/220/240; Usable Volume: 21.2 L, 1295 Cu Inches | Avl | RFQ |
5973-6890 | 6630-01-466-9947 | Special Features: Msd/Ds Turbo El Bundle; Includes: Msd, Chemstation (Nt), Software (B.00.01), And Printer (Lj4000); Interfaces With 6890 Plus Gc And 7683 Injector For Msd; Includes 100 Psi Split/Splitless Inlet, And One G2613a Autoinjector Part Name Assigned By Controlling Agency: Gas Chromatograph/Mass Spectrometer System: Unit Of Issue Cube: 4.00 Cubic Feet | Avl | RFQ |
5975 MSD | 6630-01-537-8048 | Part Name Assigned By Controlling Agency: Gas Chromatography/Mass Selective Detector Overall Width: 34.560 Inches Nominal Overall Height: 19.690 Inches Nominal | Avl | RFQ |
5975C INERT GC MSD | 6630-01-559-0223 | Special Features: Noncoated Inert Ei Source For Turbomolecular Pumps; Monolithic Hyperbolic Quadrupole Mass Filter; Em Detector With Replaceable Horn; Up To 10000 U/S Scan Rate; 65 L/S Diffusion Pump, 70 L/S Or 262 L/S Turbomolecular Pump | Avl | RFQ |
5985B-E01 | 6630-01-146-7717 | General Characteristics Item Description: C/O Crt, Control Terminal; High Speed Thermal Graphics Lineprinter; Priority Pollutant Software; Processor-Controlled Gas Chromatograph; Autotune; Ci/Ei Dual Source; Batch Processor; Gc/Ms Interface; Data System; Hyperbolic Quadrupole; Full Digital Gc And Ms; Power Reqs, 220Vac, 60Hz, Single Phase, 40 Amps | Avl | RFQ |
6410 TRIPLE QUADRUPOLE LC MS MS | 6630-01-559-0221 | Special Features: Triple Quadrupole Lc/Ms; 20:1 Signal To Noise Ratio; 3 Settings; 5200 U/Sec Scan Rate; 5 Scan Modes; Intersegment Delay Of 1.5 Sec; Single Point Data System; Electrospray; Nanospray With Hlpc-Chip Cube Ms Interface; One Triple-Stage Turbo-Molecular Pump; Countercurrent Gas | Avl | RFQ |
6630-0000-0000 | 6630-01-255-6842 | General Characteristics Item Description: C/O Sparging Vessel, Automatic Dry Air Purge, Dynamic Head Space Analyzer, Variable Size Absorption Trap And Flash Thermal Desorption Unit All Plumbed To Sub-Ambient Gas Chromatograph | Avl | RFQ |
6630-1705-0752 | 6630-01-268-1670 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
6630-1705-0752 | 6630-01-268-1671 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
6630-1705-0752 | 6630-01-268-1671 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
6630-1705-0752 | 6630-01-151-6741 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
6630-1705-0752 | 6630-00-453-6957 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
6630-1705-0752 | 6630-01-268-1670 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
6630-1705-0752 | 6630-01-268-1672 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
6630-1705-0842 | 6630-01-063-7267 | General Characteristics Item Description: 117 Vac, 50/60 Hz, Consists Of 9 Detectors, 1 Amplifier, 1 Control Console, 1 Column Oven, Oven Capacity 10, 000 Cm Reference Number Differentiating Characteristics: As Differentiated By An Extra Long Refeence Number Extra Long Reference Number: 0331-9100/0331-0006/0331-4004/0331-3115/0331-8280/0331-2201/0331-1000/0332-0118 | Avl | RFQ |
6630-1705-0842 | 6630-01-072-6186 | General Characteristics Item Description: 117 Vac, 50/60 Hz, Consists Of 9 Detectors, 1 Amplifier, 1 Control Console, 1 Column Oven, Oven Capacity 10, 000 Cm Reference Number Differentiating Characteristics: As Differentiated By An Extra Long Refeence Number Extra Long Reference Number: 0331-9100/0331-0006/0331-4004/0331-3115/0331-8280/0331-2201/0331-1000/0332-0118 | Avl | RFQ |
6630-1716-0752 | 6630-01-055-2705 | General Characteristics Item Description: Column Oven-Double Wall-Capacity Max. 60 Ft. X 1/8 In. Od Or 30 Ft. Of 1/4 In. Od Columns, Temp Range -50 Deg C. To 399 Deg C., Temp Programmer-Auto Digital, Repeatability 0.1 Pct, Detector, Injector And Auxiliary Temp Controllers, Flame Ionization Detector-Dual Grounded Jet, Electrometer-Two Stage Bipolar Design, Output-Recorder 1Mv Full Scale With Binary Output Attenuator 1-1024, Computer-10V Per Scale, Thermal Conductivity Detector-Dual, Four Passivated Tungstenrhenium Filaments, Electron Capture Detector-Type-15 Mc Ni63source Plated Directly On Coaxial Chamber, Size-18.500 X 22.250 X 19.000, Power Consumption-1800 Va Max., 115-230V Plus Or Minus Single Or Split Phase, 48-66 Hz. | Avl | RFQ |
6630-1716-0842 | 6630-01-196-3501 | NA | Avl | RFQ |
6890 | 6630-01-529-0859 | Special Features: Operating Temp. 15 Degc To 35 Degc Part Name Assigned By Controlling Agency: Agilent 6890N Network Gas Chromatograph Overall Length: 26.800 Inches Nominal | Avl | RFQ |
6890 5973N SYSTEM | 6630-01-495-1617 | NA | Avl | RFQ |
6890 SERIES GC | 6630-01-451-7040 | Special Features: 3Up To 13 Channels Of Electronic Pneumatics Control; Pressure Pulse Operation Of Split And Splitless Injection; On-Board Sensors Monitoring Ambient Temp And Barometric Pressure; 6 Independently Controlled Heat Zones; Thermal Isolation Of Valves | Avl | RFQ |
6890N W ACCESSORIES | 6630-01-268-1670 | General Characteristics Item Description: C/O Gas Chromatograpy With Hall Detector Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Injectors, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
6890N W ACCESSORIES | 6630-01-268-1670 | General Characteristics Item Description: C/O Gas Chromatograpy With Hall Detector Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Injectors, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
6890N W HELIUM ACCESSORIES | 6630-01-268-1671 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
6890N W HELIUM ACCESSORIES | 6630-01-268-1671 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
700-00 | 6630-01-047-3867 | General Characteristics Item Description: Dual Columns:0.063 To 0.500 In. O.D.-2.0 To 50.0 Ft L, Thermal Conductivity Detection, Ambient To 400 Deg C Temp Range, Thermocouple Monitor, Housed In Two Matching Cabinets: Control Contains D.C. Circuits, Oven Contains Gas Flow Systems, Injection Port Block, Column Oven, Detector Block And A.C. Heater Circuits, Main Power Supply 110/125 Vac, 50/60 Hz, 20 Amps, Detection Bridge 12 Vdc, 20 Milliamps, Carrier Gas Regulator Range 0 To 60 Psig | Avl | RFQ |
700R-3199F | 6630-01-064-2896 | NA | Avl | RFQ |
7621A | 6630-01-053-6293 | General Characteristics Item Description: Dual Type, Flame Ionization, 115 Volts, 50/60 Hz | Avl | RFQ |
7626A | 6630-01-052-8325 | General Characteristics Item Description: Dual Flame And Dual Thermal Conductivity, 115 Volt, 50/60 Hz | Avl | RFQ |
7670A | 6630-01-052-8324 | General Characteristics Item Description: Sample Tray With 36 Positions, Automatic, Manual Or Remote Choice, 115/230 Volts, 50/60 Hz, 100 Watts | Avl | RFQ |
7890A GC | 6630-01-572-8677 | Part Name Assigned By Controlling Agency: Agilent 7890A Network Gas Chromatograph Overall Length: 22.900 Inches Nominal Overall Width: 20.200 Inches Nominal | Avl | RFQ |
8202 | 6630-01-004-6629 | General Characteristics Item Description: Measures Carbon Monoxide, Methane, And Total Hydrocarbon In Ambient Air, Range 1, 2, 5, 10, 20, 50, And 100 Ppm Full Scale For Each Component, Power Requirements 105 To 125 Volts, 50 Or 60 Hz At 500 Watts, Case Size 22 In. W By 41 In. H By 23 In. Dp | Avl | RFQ |
98-1404 | 6630-01-466-9947 | Special Features: Msd/Ds Turbo El Bundle; Includes: Msd, Chemstation (Nt), Software (B.00.01), And Printer (Lj4000); Interfaces With 6890 Plus Gc And 7683 Injector For Msd; Includes 100 Psi Split/Splitless Inlet, And One G2613a Autoinjector Part Name Assigned By Controlling Agency: Gas Chromatograph/Mass Spectrometer System: Unit Of Issue Cube: 4.00 Cubic Feet | Avl | RFQ |
G1530A G2579A G1916A | 6630-01-495-1617 | NA | Avl | RFQ |
G2802A | 6630-01-576-3752 | Special Features: Power Supply Input Connector, Remote Start Part Name Assigned By Controlling Agency: Channel Systems End Item Identification: Agilent 3000 Micro Gc | Avl | RFQ |
G3172A | 6630-01-537-8048 | Part Name Assigned By Controlling Agency: Gas Chromatography/Mass Selective Detector Overall Width: 34.560 Inches Nominal Overall Height: 19.690 Inches Nominal | Avl | RFQ |
G3174A | 6630-01-585-2556 | Special Features: 5975C Inert Xl Msd Performance-Turbo Ei/Pci/Nci Mainframe;Triple-Axis Dector;For Gc/Ms Analyses;Synchronous Sim/Scan Functionality;Integrates Amdis Reults Into Qedit And Reports Functions;Trace Ion Detection And Drs, Mdl And Loq;True Hyperbolic Quartz Structure Part Name Assigned By Controlling Agency: Gas Chromatograph End Item Identification: Instrumentation;Testing Equipment | Avl | RFQ |
G3440A | 6630-01-563-3962 | Special Features: Leak-Free In-Oven Connections; Tracks Usage Of Supplies And Monitors Chromatographic Quality; Turn Top Design; Gasses Are Supplied By Tanks, Internal Distribution System Or Gas Generators | Avl | RFQ |
G6890N | 6630-01-553-4210 | Special Features: Two Injectors Isothermal Split/Splitless Capillary W/Electronic Flow Control; Multi-Level Temperature Programmable To A Maximum Temperature Of 450 Deg C W/Pressure Range 0 Min. 100 Psi And Split Range Of 1 - 7500 Psi; Valve System For Analytical Columns Protection; Two Detectors Thermal Conductivity Detector, Dual Independent W/Electronic Flow Control And Flame Ionisation Detector W/Electronic Flow Control; Data Station Inculdes 3.4 Ghz Pentium 4 Processor, 1.0 Gb Ram, 1.44 Mb Floppy Drive, 2 Pci Slots, 2 Serial Ports, 1 Parallel Port, 8 Usb 2.0 Ports, Windows Xp Professinal Sp2 And 17 Inch Flat Panel Display Screen Overall Length: 21.600 Inches Nominal Overall Width: 22.800 Inches Nominal | Avl | RFQ |
G6890N 5975B | 6630-01-553-4199 | Special Features: Gas Chromatograph W/Mass Spectrometer; Operating Temperature 450 Deg C Max; Includes Two Injectors Isothermal Split/Splitless Capillary W/Electronic Flow Control; Two Detectors Ion Trap Or Linear Quadrupole; Maximum Scan Speed Of 5, 000 U/Sec Or Better; Data Station W/Windows Sp Professional Sp2, 3.4 Ghz Pentium 4 Processor, 1.0 Gb Ram, 2 Pci Slots, 2 Serial Ports, 1 Parallel Port, 8 Usb 2.0 Ports, 17 Inch Flat Panel Display, Nist Library Overall Length: 21.600 Inches Nominal Overall Width: 22.800 Inches Nominal | Avl | RFQ |
G7100A | 6630-01-600-9406 | Special Features: Includes Lab Advisor Sw, Inst. Qualif. Kit, High Sesitivity Cell & Services. Part Name Assigned By Controlling Agency: Agilent 7100 Capillary Electrophoresis Instrument | Avl | RFQ |
HP 6890 SERIES GC | 6630-01-451-7040 | Special Features: 3Up To 13 Channels Of Electronic Pneumatics Control; Pressure Pulse Operation Of Split And Splitless Injection; On-Board Sensors Monitoring Ambient Temp And Barometric Pressure; 6 Independently Controlled Heat Zones; Thermal Isolation Of Valves | Avl | RFQ |
N260-0022 | 6630-01-218-5176 | NA | Avl | RFQ |
N601-9100 | 6630-01-151-6741 | General Characteristics Item Description: Power Reqs 115Vac; 50/60 Hz; C/O Sigma 2000 Gas Chromatograph, P/N N601-0001; Flametonization And Hot Wire Detector 2, P/N N601-1532; Injectors For Aand B Channels, P/N N601-2210; Dual Flow Controllers For A And B Channels, P/Nn601-3330; Ten-Port Heated Automatic Valves And Liquid Carbon Dioxide Subambient Module, P/N N601-4442; Timed-Eventboard, P/N N601-5001; Chromatographics 2, P/N N335-0077; Complete | Avl | RFQ |
N601-9100 N601-1122 | 6630-01-268-1672 | General Characteristics Item Description: Basic Sigma 2000 Gc With Fid/Npd Detectors Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
N601-9100 N601-1430 | 6630-01-268-1671 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
N601-9100 N601-1430 | 6630-01-268-1671 | General Characteristics Item Description: C/O Chromatograph With Ecd/Hwd Detectors Includes N601-2120 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci 100 Computing Integrator | Avl | RFQ |
N601-9100 N601-1980 | 6630-01-268-1670 | General Characteristics Item Description: C/O Gas Chromatograpy With Hall Detector Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Injectors, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
N601-9100 N601-1980 | 6630-01-268-1670 | General Characteristics Item Description: C/O Gas Chromatograpy With Hall Detector Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Injectors, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
N601-9100KA | 6630-01-268-1672 | General Characteristics Item Description: Basic Sigma 2000 Gc With Fid/Npd Detectors Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Pneumatics, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
N601-9100KC | 6630-01-268-1670 | General Characteristics Item Description: C/O Gas Chromatograpy With Hall Detector Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Injectors, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
N601-9100KC | 6630-01-268-1670 | General Characteristics Item Description: C/O Gas Chromatograpy With Hall Detector Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Injectors, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
N611-9000 WITH ACCESSORIES | 6630-01-268-1670 | General Characteristics Item Description: C/O Gas Chromatograpy With Hall Detector Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Injectors, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
N611-9000 WITH ACCESSORIES | 6630-01-268-1670 | General Characteristics Item Description: C/O Gas Chromatograpy With Hall Detector Including N601-2110 Packed Column Injectors, N601-3330 Packed Column Injectors, N625-0001 Lci-100 Computing Integrator | Avl | RFQ |
SIGMA 1 | 6630-01-082-5498 | General Characteristics Item Description: Combines One Or More Gas Chromatographs With Integral Microprocessor Control And Data Handling;Keyboard Is Used To Set Analytical Parameters;Microprocessor Capable Of Simultaneously Controlling 2 Analyzer Units And Reduce Data From As Many As Four Detectors;Internal Printer/Plotter Gives Complete Report;High Performance Thermally Protected Column Oven;Oven Temperature Range -100 To 450 Deg Centigrade;Power Requirements 117 Volts, 50/60 Hertz | Avl | RFQ |
SIGMA 2 | 6630-01-072-6186 | NA | Avl | RFQ |
SIGMA 300 | 6630-01-196-3501 | NA | Avl | RFQ |
SIGMA2000 | 6630-01-151-6741 | General Characteristics Item Description: Power Reqs 115Vac; 50/60 Hz; C/O Sigma 2000 Gas Chromatograph, P/N N601-0001; Flametonization And Hot Wire Detector 2, P/N N601-1532; Injectors For Aand B Channels, P/N N601-2210; Dual Flow Controllers For A And B Channels, P/Nn601-3330; Ten-Port Heated Automatic Valves And Liquid Carbon Dioxide Subambient Module, P/N N601-4442; Timed-Eventboard, P/N N601-5001; Chromatographics 2, P/N N335-0077; Complete | Avl | RFQ |
All Orders are Fulfilled in the U.S.A.
All shipments must comply with U.S.A export laws.
No exceptions.
The only independent distributor
with a NO CHINA SOURCING Pledge
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
Remember Us the Next Time You’re Looking for NSN Parts. We Can Get You Some of the Quickest and Most Competitive Quotes In the Industry.
Request for Quote