We’re pleased to announce that CDLS17228 (Switch Liquid Level, NSN: 5930-00-758-5744) is now in stock and ready for immediate quoting. This component, manufactured by Gems Sensors Inc (CAGE Code: 04034), is classified under NIIN 00-758-5744 and NCB Code 00 (USA), with additional categorization under FSG 59 Electrical and Electronic Equipment Components/FSC 5930 Switches and INC 37187. Our team can provide same-day shipping for urgent requirements.
To receive your competitive quote within 15 minutes, simply complete our RFQ form part CDLS17228, ensuring all required fields are filled. Our streamlined process guarantees fast, no-obligation pricing so you can secure your supply of CDLS17228 without delay. Contact us today to meet your procurement needs efficiently
ASAP Part Services, a trusted subsidiary of ASAP Semiconductor, is a premier distributor of Gems Sensors Inc components—specializing in obsolete and hard-to-find parts. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified supplier, we adhere to the highest industry standards under the Aviation Suppliers Association (ASA). Our global network spans 5,000+ top manufacturers, ensuring access to over 2 billion unique parts for critical needs.
With strategically located shipping centers in California, we offer rapid same-day or next-day delivery on in-stock items like CDLS17228. Whether you're sourcing rare components or need expedited logistics, we provide reliable solutions to keep your operations moving forward.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-758-5744 Item PartTypeName: SWITCH,LIQUID LEVEL | 5930 | 007585744 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
LS17228 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ACYN | AC VOLTAGE RATING | UNABLE TO DECODE110.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACYN | AC VOLTAGE RATING | UNABLE TO DECODE220.0 VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | UNABLE TO DECODE60.0 HERTZ NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
AFLW | ACTUATION METHOD | BUOYANCY |
AGBD | ELECTRICAL CONNECTION TYPE | CONNECTOR RECEPTACLE |
ALSF | INTERNAL BATTERY ACCOMMODATION | UNABLE TO DECODENOT INCLUDED 2ND ALTERNATE OPERATING POWER RQMT |
APGY | VOLTAGE RATING AT MAXIMUM RATED CURRENT | 110.0 VOLTS |
AWAE | FLOAT QUANTITY | 2 |
AXGY | MOUNTING METHOD | FLANGE |
BJKC | MAXIMUM CURRENT RATING | 0.08 AMPERES RESISTIVE LOAD |
BJKP | MOUNTING DIMENSIONS | MTD BY FOUR 3/4 IN. HOLES EQUALLY SPACED ON A 5-1/2 IN. BOLT CIRCLE |
BJKQ | TANK INSERTION LENGTH | 31.000 INCHES NOMINAL |
ABHP | OVERALL LENGTH | 33.250 INCHES NOMINAL |
ACYR | DC VOLTAGE RATING | UNABLE TO DECODE32.0 VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | UNABLE TO DECODE6.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | UNABLE TO DECODE60.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ADAV | OVERALL DIAMETER | 7.000 INCHES NOMINAL |
ALSF | INTERNAL BATTERY ACCOMMODATION | UNABLE TO DECODENOT INCLUDED 1ST ALTERNATE OPERATING POWER RQMT |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.04 AMPERES RESISTIVE LOAD |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 250.0 DEG FAHRENHEIT MAXIMUM |
BBJX | MOUNTING POSITION | VERTICAL |
BJKD | CONTACT ARRANGEMENT | SINGLE POLE,SINGLE THROW,NORMALLY OPEN |
BJKG | RELAY | NOT INCLUDED |
BJKH | LIQUID TYPE FOR WHICH DESIGNED | FUEL,NONAIRCRAFT AND HYDRAULIC OIL AND LUBRICATING OIL AND SEA WATER |
End Use : 21100 | Industrial engines |
---|---|
Schedule B : 8413919520 (NAICS 333911) | Parts, nesoi, of pumps for liquids |
SITC : 74291 | Parts of pumps for liquids |
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
---|---|
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | A - Item does not contain precious metal. |
AAC | J |
---|---|
Classification Control | U |
MGMT_CTL | 9b----- |
Quantity per pack | 1 |
Repariability | |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LCL: | P - 77.5 |
LTL: | P - 77.5 |
NMFC: | 061300 - Circuit breaker/switch noi |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components |
Quotes within 15 minutes |
|
Competitive Prices |
|
Dedicated and Knowledgeable |
|
AOG Services 24/7 x 365 |
|
Same-day |
Remember Us the Next Time You’re Looking for NSN Parts. We Can Get You Some of the Quickest and Most Competitive Quotes In the Industry.