We’re pleased to announce that SP314 (Transformer Power, NSN: 5950-00-513-0922) is now in stock and ready for immediate quoting. This component, manufactured by Standard Electronics Corp (CAGE Code: 90234), is classified under NIIN 00-513-0922 and NCB Code 00 (USA), with additional categorization under FSG 59 Electrical and Electronic Equipment Components/FSC 5950 Coils and Transformers and INC 32496. Our team can provide same-day shipping for urgent requirements.
To receive your competitive quote within 15 minutes, simply complete our RFQ form part SP314, ensuring all required fields are filled. Our streamlined process guarantees fast, no-obligation pricing so you can secure your supply of SP314 without delay. Contact us today to meet your procurement needs efficiently
ASAP Part Services, a trusted subsidiary of ASAP Semiconductor, is a premier distributor of Standard Electronics Corp components—specializing in obsolete and hard-to-find parts. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified supplier, we adhere to the highest industry standards under the Aviation Suppliers Association (ASA). Our global network spans 5,000+ top manufacturers, ensuring access to over 2 billion unique parts for critical needs.
With strategically located shipping centers in California, we offer rapid same-day or next-day delivery on in-stock items like SP314. Whether you're sourcing rare components or need expedited logistics, we provide reliable solutions to keep your operations moving forward.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-513-0922 Item PartTypeName: TRANSFORMER,POWER | 5950 | 005130922 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
627439 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.844 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.906 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.969 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.031 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 5.625 INCHES MINIMUM AND 5.875 INCHES MAXIMUM |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO TWO PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | SCOTT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.750 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.875 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED WITH OIL |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.190 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 7.7 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.45 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 24.89 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.45 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 30.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY24.89 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 2.45 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 90.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY30.50 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY24.89 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | EXTERNAL JUMPER REQUIRED FOR SUGGESTED SCOTT-T OPERATION |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 14 TURRET |
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
---|---|
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | U - Precious metal content is unknown |
AAC | Y |
---|---|
Classification Control | U |
MGMT_CTL | 9b----- |
Quantity per pack | 1 |
Repariability | |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LTL: | W - Rating variable |
NMFC: | 063420 - Transformers, noi, or transformer par |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 595 - Transformer, (machinery and parts),(less than 35 feet) |
Quotes within 15 minutes |
|
Competitive Prices |
|
Dedicated and Knowledgeable |
|
AOG Services 24/7 x 365 |
|
Same-day |
Remember Us the Next Time You’re Looking for NSN Parts. We Can Get You Some of the Quickest and Most Competitive Quotes In the Industry.
Request for Quote