We’re pleased to announce that TTI-14-250 (Transformer Power, NSN: 5950-01-346-9706) is now in stock and ready for immediate quoting. This component, manufactured by Transformer Technicians Inc (CAGE Code: 96253), is classified under NIIN 01-346-9706 and NCB Code 01 (USA), with additional categorization under FSG 59 Electrical and Electronic Equipment Components/FSC 5950 Coils and Transformers and INC 32496. Our team can provide same-day shipping for urgent requirements.
To receive your competitive quote within 15 minutes, simply complete our RFQ form part TTI-14-250, ensuring all required fields are filled. Our streamlined process guarantees fast, no-obligation pricing so you can secure your supply of TTI-14-250 without delay. Contact us today to meet your procurement needs efficiently
ASAP Part Services, a trusted subsidiary of ASAP Semiconductor, is a premier distributor of Transformer Technicians Inc components—specializing in obsolete and hard-to-find parts. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified supplier, we adhere to the highest industry standards under the Aviation Suppliers Association (ASA). Our global network spans 5,000+ top manufacturers, ensuring access to over 2 billion unique parts for critical needs.
With strategically located shipping centers in California, we offer rapid same-day or next-day delivery on in-stock items like TTI-14-250. Whether you're sourcing rare components or need expedited logistics, we provide reliable solutions to keep your operations moving forward.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-346-9706 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013469706 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TTI-14-250 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
BFMF | COOLING METHOD | SELF-COOLED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 32.50 AC VOLTS MINIMUM SINGLE COMPONENT 1ST SECONDARY AND 33.50 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
ABHP | OVERALL LENGTH | 3.440 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.062 INCHES MINIMUM AND 2.680 INCHES MAXIMUM |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA AND WYE-WYE |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
CRBZ | WINDING OPERATING CURRENT | 55.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 18.50 AC VOLTS MINIMUM SINGLE COMPONENT 3RD SECONDARY AND 21.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 200.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNALLY SHIELDED SINGLE COMPONENT |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 32.50 AC VOLTS MINIMUM SINGLE COMPONENT 2ND SECONDARY AND 33.50 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.985 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.550 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.143 INCHES MINIMUM SINGLE GROUP AND 0.158 INCHES MAXIMUM SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CRMJ | WINDING POWER RATING | 11.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
TEST | TEST DATA DOCUMENT | 99167-5907286 DRAWING THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC. EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 13 WIRE LEAD |
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
---|---|
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | A - Item does not contain precious metal. |
AAC | J |
---|---|
Classification Control | U |
MGMT_CTL | Sf9eh-n |
Quantity per pack | No qup |
Repariability | |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LTL: | W - Rating variable |
NMFC: | 063420 - Transformers, noi, or transformer par |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 595 - Transformer, (machinery and parts),(less than 35 feet) |