We’re pleased to announce that M5600 (Switch Liquid Level, NSN: 5930-00-409-9261) is now in stock and ready for immediate quoting. This component, manufactured by Velcon Filters Inc (CAGE Code: 13573), is classified under NIIN 00-409-9261 and NCB Code 00 (USA), with additional categorization under FSG 59 Electrical and Electronic Equipment Components/FSC 5930 Switches and INC 37187. Our team can provide same-day shipping for urgent requirements.
To receive your competitive quote within 15 minutes, simply complete our RFQ form part M5600, ensuring all required fields are filled. Our streamlined process guarantees fast, no-obligation pricing so you can secure your supply of M5600 without delay. Contact us today to meet your procurement needs efficiently
ASAP Part Services, a trusted subsidiary of ASAP Semiconductor, is a premier distributor of Velcon Filters Inc components—specializing in obsolete and hard-to-find parts. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified supplier, we adhere to the highest industry standards under the Aviation Suppliers Association (ASA). Our global network spans 5,000+ top manufacturers, ensuring access to over 2 billion unique parts for critical needs.
With strategically located shipping centers in California, we offer rapid same-day or next-day delivery on in-stock items like M5600. Whether you're sourcing rare components or need expedited logistics, we provide reliable solutions to keep your operations moving forward.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5930-00-409-9261 Item PartTypeName: SWITCH,LIQUID LEVEL | 5930 | 004099261 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
M5600 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.375 INCHES NOMINAL |
ABJP | POWER CABLE LENGTH | 24.000 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 110.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACYN | AC VOLTAGE RATING | 220.0 VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | 32.0 VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ACYR | DC VOLTAGE RATING | 6.0 VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
ADAV | OVERALL DIAMETER | 2.000 INCHES NOMINAL |
AFLW | ACTUATION METHOD | BUOYANCY |
AGBD | ELECTRICAL CONNECTION TYPE | CABLE |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED 1ST ALTERNATE OPERATING POWER RQMT |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED 2ND ALTERNATE OPERATING POWER RQMT |
APGW | CURRENT RATING AT MAXIMUM RATED VOLTAGE | 45.0 MILLIAMPERES NOMINAL LOAD |
APGY | VOLTAGE RATING AT MAXIMUM RATED CURRENT | 110.0 VOLTS |
AWAE | FLOAT QUANTITY | 1 |
AWTN | OPERATING TEMP RATING | 0.0 DEG FAHRENHEIT NOMINAL AND 250.0 DEG FAHRENHEIT NOMINAL |
AXGY | MOUNTING METHOD | THREAD |
BBJX | MOUNTING POSITION | VERTICAL |
BJKC | MAXIMUM CURRENT RATING | 90.0 MILLIAMPERES NOMINAL LOAD |
BJKD | CONTACT ARRANGEMENT | SINGLE POLE SINGLE THROW NORMALLY OPEN IN DRY CONDITION-NORMALLY CLOSED BY INVERTING FLOAT ON STEM |
BJKG | RELAY | NOT INCLUDED |
BJKH | LIQUID TYPE FOR WHICH DESIGNED | VARIOUS FUELS |
BJKN | FLOAT EFFECTIVE TRAVEL | 1.000 INCHES NOMINAL |
BJKP | MOUNTING DIMENSIONS | 0.250NPT MALEW/NUT 0.625HEX |
BJKQ | TANK INSERTION LENGTH | 2.375 INCHES NOMINAL |
FAAZ | PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
FAAZ | PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
End Use : 21100 | Industrial engines |
---|---|
Schedule B : 8413919520 (NAICS 333911) | Parts, nesoi, of pumps for liquids |
SITC : 74291 | Parts of pumps for liquids |
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
---|---|
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | U - Precious metal content is unknown |
AAC | Z |
---|---|
Classification Control | U |
MGMT_CTL | Q2200x- |
Quantity per pack | 1 |
Repariability | This is a nonreparable item. if condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LCL: | P - 77.5 |
LTL: | P - 77.5 |
NMFC: | 061300 - Circuit breaker/switch noi |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 72D - Communications/electronics, other than sigint/ew or comsec repair parts and components |
Quotes within 15 minutes |
|
Competitive Prices |
|
Dedicated and Knowledgeable |
|
AOG Services 24/7 x 365 |
|
Same-day |
Remember Us the Next Time You’re Looking for NSN Parts. We Can Get You Some of the Quickest and Most Competitive Quotes In the Industry.
Request for Quote