We’re pleased to announce that 241-0-80A-400CY (Ammeter, NSN: 6625-01-159-6857) is now in stock and ready for immediate quoting. This component, manufactured by Westinghouse Electric Corp (CAGE Code: 11660), is classified under NIIN 01-159-6857 and NCB Code 01 (USA), with additional categorization under FSG 66 Instruments and Laboratory Equipment/FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments and INC 16450. Our team can provide same-day shipping for urgent requirements.
To receive your competitive quote within 15 minutes, simply complete our RFQ form part 241-0-80A-400CY, ensuring all required fields are filled. Our streamlined process guarantees fast, no-obligation pricing so you can secure your supply of 241-0-80A-400CY without delay. Contact us today to meet your procurement needs efficiently
ASAP Part Services, a trusted subsidiary of ASAP Semiconductor, is a premier distributor of Westinghouse Electric Corp components—specializing in obsolete and hard-to-find parts. As an AS9120B, ISO 9001:2015, and FAA AC 0056B certified supplier, we adhere to the highest industry standards under the Aviation Suppliers Association (ASA). Our global network spans 5,000+ top manufacturers, ensuring access to over 2 billion unique parts for critical needs.
With strategically located shipping centers in California, we offer rapid same-day or next-day delivery on in-stock items like 241-0-80A-400CY. Whether you're sourcing rare components or need expedited logistics, we provide reliable solutions to keep your operations moving forward.
MRC | Criteria | Characteristic |
---|---|---|
APPN | Accuracy In Percent | -1.5/+1.5 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE |
ABKR | Center To Center Distance Between Mounting Facilities Parallel To Width | 3.376 INCHES NOMINAL |
AMQY | Installation Design | PANEL |
MRC | Decoded Requirement | Clear Text Reply |
ASSS | Pointer Color | BLACK SINGLE INDICATOR SINGLE RANGE |
APSN | Panel For Which Designed | UNABLE TO DECODE |
APST | Meter Depth Behind Mounting Flange | 2.813 INCHES NOMINAL |
APSW | Meter Body Diameter Behind Mounting Flange | 3.960 INCHES NOMINAL |
CTTD | Circuit Attachment Method And Quantity | 2 THREADED STUD |
ABMK | Overall Width | 4.422 INCHES NOMINAL |
ABHP | Overall Length | 4.062 INCHES NOMINAL |
ADAG | Mounting Stud Length | 0.625 INCHES NOMINAL |
ABWG | Scale Division Quantity | 40 SINGLE INDICATOR SINGLE RANGE |
AKYN | Furnished Items And Quantity | MTG HARDWARE 4; TERM. HARDWARE |
ANRL | Mounting Arrangement Style | FOUR HOLE/STUD RECTANGULAR/SQUARE |
FEAT | Special Features | 400 HZ XFRMR REQUIRED |
CBBL | Features Provided | ZERO ADJUSTER |
ANSY | Frequency Response Range | +0.025/+1.000 KILOHERTZ |
BHDC | Scale Graduation Type | LINEAR SINGLE INDICATOR SINGLE RANGE |
ABKW | Overall Height | 4.422 INCHES NOMINAL |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR SINGLE RANGE |
NHCF | Nuclear Hardness Critical Feature | NONHARDENED |
STYL | Style Designator | RECTANGULAR FLUSH MTG |
AACT | Circuit Current For Which Designed | AC |
BHMW | Measurement Range | +0.0/+80.0 AMPERES, AC SINGLE INDICATOR SINGLE RANGE |
AMKD | Indicator Type | DIAL W/POINTER |
BHSX | Circuit Construction Type | UNABLE TO DECODE |
ABKQ | Center To Center Distance Between Mounting Facilities Parallel To Length | 3.376 INCHES NOMINAL |
AQEC | Movement Type | MOVING COIL, PERMANENT MAGNET |
CTQL | Movement Suspension Method | TAUT BAND |
End Use : 21160 | Measuring, testing, control instruments |
---|---|
Schedule B : 9030908030 (NAICS 334515) | Parts and accessories of articles of schedule b subheading 9030.39 |
SITC : 87479 | Parts and accessories for instruments and apparatus (except meters) measuring etc. Electrical quanities and devices measuring etc. Ionized radiations |
ADPE | Represents items with no adp components |
---|---|
CRITL | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
HMIC | P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of federal standard 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item. |
PMIC | A - Item does not contain precious metal. |
AAC | X |
---|---|
Classification Control | U |
MGMT_CTL | 9b----- |
Quantity per pack | 1 |
Repariability | |
Shelf Life | N/A |
SOS | Sms |
Unit of Measure | Ea |
ACC: | H - Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
---|---|
ADC: | A - Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
LTL: | W - Rating variable |
NMFC: | 136740 - Meters elec/parts |
SHC: | 9 - Other or no special handling required (sh) |
TCC: | Z - No special type of cargo code applicable |
WCC: | 657 - Instruments, electric meter |
Quotes within 15 minutes |
|
Competitive Prices |
|
Dedicated and Knowledgeable |
|
AOG Services 24/7 x 365 |
|
Same-day |
Remember Us the Next Time You’re Looking for NSN Parts. We Can Get You Some of the Quickest and Most Competitive Quotes In the Industry.